Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.909
Filtrar
1.
J Orthop Surg Res ; 19(1): 253, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38644485

RESUMO

INTRODUCTION: We present a detailed procedure for the robotic-assisted plate osteosynthesis of an anterior acetabular fracture. The purpose of this work was to describe a robotic-assisted minimally invasive technique as a possible method for reducing complications, pain, and hospitalization. Another goal was to present technical recommendations and to assess potential pitfalls and problems of the new surgical approach. METHODS: Surgery was performed in an interdisciplinary setting by an experienced orthopedic surgeon and a urologist. The DaVinci System with standard instruments was used. Reduction was achieved through indirect traction of a pin that was introduced into the femoral neck and direct manipulation via the plate. The plate position and fixation were achieved through 7 additional minimally invasive incisions. RESULTS: The technique has multiple advantages, such as no detachment of the rectus abdominal muscle, a small skin incision, and minimal blood loss. Furthermore, this approach might lower the incidence of hernia formation, infection, and postoperative pain. DISCUSSION: We see the presented technique as a demanding yet progressive and innovative surgical method for treating acetabular fractures with indications for anterior plate fixation. TRIAL REGISTRATION: The study was approved by the local institutional review board (Nr. 248/18).


Assuntos
Acetábulo , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Ósseas , Procedimentos Cirúrgicos Robóticos , Humanos , Acetábulo/cirurgia , Acetábulo/lesões , Procedimentos Cirúrgicos Robóticos/métodos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Feminino , Adulto
2.
Acta Ortop Mex ; 38(1): 10-14, 2024.
Artigo em Espanhol | MEDLINE | ID: mdl-38657146

RESUMO

INTRODUCTION: health promotion policy requires the identification of barriers to the adoption of public policies. Paraguay's national healthcare system is inequitable, expensive, and inefficient. The Ministry of Public Health and Social Welfare (MSPyBS) is the entity responsible for covering the needs of a significant portion of the population. In January 2022, the MSPyBS financed the purchase of titanium elastic nails through a National Public Tender for Osteosynthesis Materials (LPN 02/22) to provide them for free in the pediatric service. Using research as a tool, we seek to analyze the impact of the implementation of LPN 02/22 at the Trauma Hospital, believing that this action would help streamline administrative and bureaucratic processes, making them more efficient with the assistance of the hospital's human resources. MATERIAL AND METHODS: a retrospective, analytical, and comparative study conducted at a high-complexity trauma center in Asunción, Paraguay. Patients aged 4 to 14 years with an indication for stabilization with elastic nails were included. Demographic data, the mechanism of injury, time elapsed from hospital arrival to surgical treatment, length of hospital stay, and the average hospital cost were analyzed based on the daily expense of pediatric patient hospitalization. RESULTS: 52 patients, divided into 25 cases in 2021 before implementation and 27 cases after implementation. The time elapsed from hospital arrival to definitive treatment was six days in the pre-implementation period, with an average stay from admission to discharge of 7.4 days. After implementation, the time from hospital arrival to definitive treatment was 4.3 days, and the average discharge time for the Post group was six days. The potential savings per patient amount to 332 dollars, offset by the institution's implant supply cost of 197 dollars, resulting in an approximate savings of 135 dollars per patient for the ministry. CONCLUSIONS: we view the implementation of free titanium elastic nails for pediatric femur fracture patients positively. We encourage the institution to continue with similar policies and strive to achieve even greater benefits for users.


INTRODUCCIÓN: la política de promoción de la salud requiere la identificación de los obstáculos para la adopción de políticas públicas. El sistema nacional de salud de Paraguay es inequitativo, caro e ineficiente. El Ministerio de Salud Pública y Bienestar Social (MSPyBS) es el ente que cubre las necesidades de gran parte de la población. El MSPyBS en Enero del 2022 financió, mediante la Licitación Pública Nacional de Materiales de Osteosíntesis (LPN 02/22), la compra de clavos elásticos de titanio para disponer de su uso gratuito en el Servicio de Pediatría; usando a la investigación como herramienta, buscamos analizar el impacto de la implementación de la LPN 02/22 en el Hospital de Trauma, creyendo que esta acción ayudaría a dinamizar los procesos administrativos y burocráticos, haciéndolos más eficientes con la ayuda de los recursos humanos del hospital. MATERIAL Y MÉTODOS: estudio retrospectivo, analítico y comparativo, realizado en un centro de trauma de alta complejidad de Asunción, Paraguay. Fueron incluidos los pacientes con edad comprendidas entre cuatro y 14 años, con indicación de estabilización con clavos elásticos. Se analizaron los datos demográficos, el mecanismo de trauma, el tiempo transcurrido desde la llegada al hospital hasta el tratamiento quirúrgico, así como el tiempo de estadía hospitalaria. Se evaluó el costo hospitalario promedio, basados en el gasto diario de la internación de un paciente pediátrico. RESULTADOS: cincuenta y dos pacientes, separados en 25 casos en el 2021 previo a la implementación y 27 casos posterior a la implementación. El tiempo transcurrido desde la llegada al hospital hasta el tratamiento definitivo fue de seis días para la etapa previa a la implementación; el promedio desde el ingreso hasta el alta fue de 7.4 días. Desde la implementación se tuvo un transcurso de 4.3 días desde la llegada al hospital hasta el tratamiento definitivo. El egreso del grupo Post tuvo un promedio de seis días. El ahorro probable en relación con cada paciente es de 332 dólares; a esto debemos contrarrestar el monto que paga la institución para la provisión del implante (197 dólares), por lo que el ahorro del ministerio sería de aproximadamente 135 dólares por cada paciente. CONCLUSIONES: vemos como positiva la implementación de la gratuidad de los clavos elásticos de titanio en los pacientes en edad pediátrica con fractura de fémur. Alentamos a la institución a seguir con políticas similares y tratar de lograr mayores beneficios para los usuarios.


Assuntos
Fraturas do Fêmur , Humanos , Criança , Estudos Retrospectivos , Adolescente , Pré-Escolar , Feminino , Masculino , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/economia , Paraguai , Tempo de Internação/estatística & dados numéricos , Pinos Ortopédicos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/economia , Fixação Interna de Fraturas/instrumentação , Custos Hospitalares/estatística & dados numéricos , Centros de Traumatologia/organização & administração , Titânio
3.
BMC Musculoskelet Disord ; 25(1): 320, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654260

RESUMO

BACKGROUND: The precise influence of plate position on clinical outcomes in the context of volar fixed-angle plating for distal radius fractures is not fully understood. This article aims to investigate the influence of plate position on clinical results, and functional outcomes in patients treated with volar fixed plating for distal radius fractures. METHODS: A total of 58 patients with 64 distal radius fractures were included in the study. Patient demographics, fracture characteristics, surgical details, and radiographic data were collected. Post-operative AP and Lat views of all patients taken on the first day after surgery were evaluated. Volar Tilt, Radial Inclination and Radial Height measurements were used as reduction criteria. In the follow-up, the patients were called for their last control, flexion and extension angles of the wrist and Mayo Wrist Scores, the distance of the plate to the joint line and the angle between the plate and the radial shaft were measured and recorded. RESULTS: A total of 64 distal radius fractures, with a mean age of 46.9 years, and the mean follow-up period 24.9 months were included in this study. There was a significant relationship between the Radial Inclination and Plate-Shaft Angle variables and the Mayo Wrist Score at a 99% confidence interval. Additionally, a relationship was observed between the Radial Height variable and the Mayo Score at a 90% confidence interval. A significant positive association was observed between radial inclination and achieving a Good-to-Excellent Mayo score (OR = 1.28, 95% CI [1.08-1.51], p = 0.004). Plate distance to joint line demonstrated a marginally significant positive association with a Good-to-Excellent Mayo score (OR = 1.31, 95% CI [0.97-1.77], p = 0.077). Univariate analysis revealed a significant negative association between plate-shaft angle and achieving a Good-to-Excellent Mayo score (OR = 0.71, 95% CI [0.52-0.99], p = 0.045). This negative association remained statistically significant in the multivariate analysis (p = 0.016). CONCLUSION: Radial inclination, plate distance to joint line, and angle between plate and radius shaft were identified as significant factors associated with improved Mayo Wrist Scores.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas do Rádio , Humanos , Fraturas do Rádio/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Adulto , Idoso , Resultado do Tratamento , Seguimentos , Estudos Retrospectivos , Amplitude de Movimento Articular , Adulto Jovem , Fraturas do Punho
4.
Clin Orthop Surg ; 15(6): 983-988, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38045572

RESUMO

Background: To evaluate the feasibility of treating odontoid fractures in the Chinese population with two cortical screws based on computed tomography (CT) scans and describe a new measurement strategy to guide screw insertion in treating these fractures. Methods: A retrospective review of cervical computed tomographic scans of 128 patients (aged 18-76 years; men, 55 [43.0%]) was performed. The minimum external transverse diameter (METD), minimum external anteroposterior diameter (MEAD), maximum screw length (MSL), and screw projection back angle (SPBA) of the odontoid process were measured on coronal and sagittal CT images. Results: The mean values of METD and MEAD were 10.0 ± 1.1 mm and 12.0 ± 1.0 mm, respectively, in men and 9.2 ± 1.0 mm and 11.0 ± 1.0 mm, respectively, in women. Both measurements were significantly higher in men (p < 0.001). In total, 87 individuals (68%) had METD > 9.0 mm that could accommodate two 3.5-mm cortical screws. The mean MSL value and SPBA range were 34.4 ± 2.9 mm and 13.5°-24.2°, respectively, with no statistically significant difference between men and women. Conclusions: The insertion of two 3.5-mm cortical screws was possible for anterior fixation of odontoid fractures in 87 patients (68%) in our study, and there was a statistically significant difference between men and women.


Assuntos
Fixação Interna de Fraturas , Fraturas Ósseas , Processo Odontoide , Fraturas da Coluna Vertebral , Feminino , Humanos , Masculino , Parafusos Ósseos , População do Leste Asiático , Estudos de Viabilidade , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Processo Odontoide/diagnóstico por imagem , Processo Odontoide/cirurgia , Processo Odontoide/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Tomografia Computadorizada por Raios X , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso
5.
Zhongguo Gu Shang ; 36(9): 798-803, 2023 Sep 25.
Artigo em Chinês | MEDLINE | ID: mdl-37735068

RESUMO

OBJECTIVE: To evaluate the needle puncture safety and clinical efficacy of manual reduction combined with external fixation of ankle frame in the treatment of trimalleolar fracture under the guidance of Chinese Osteosynthesis (CO) theory. METHODS: The clinical data of 118 patients with trimalleolar fractures admitted from December 2010 to December 2021 were retrospectively analyzed. Fifty-three patients were treated with manual reduction combined with external fixation of ankle frame(observation group). Sixty-five patients were treated with open reduction and internal fixation with plate and screws(control group). The operation time, hospitalization days, non-weight-bearing time of the affected limb, clinical healing time of fracture, incidence of complications, visual analogue scale (VAS) before and 1 month after operation, and American Orthopedic Foot and Ankle Society(AOFAS) score of ankle joint before and 1 year after operation were compared between the two groups. RESULTS: Patients in both groups were followed up for more than 1 year. All patients were followed up, and the duration ranged from 14 to 70 months, with an average of(35.28±14.66) months. There were statistically significant in operation time, hospitalization days, non-load-bearing time of affected limbs, clinical healing time of fractures and VAS score one month after operation between the two groups. One month after operation, the VAS score of the observation group was lower than that of the control group(t=3.343, P=0.001). The operation time of the observation group was significantly shorter than that of the control group(t=9.091, P=0.000). The hospitalization days in the observation group were significantly less than those in the control group(t=5.034, P=0.000). The non-load-bearing time of the affected limb in the observation group was significantly shorter than that in the control group(t=11.960, P=0.000). The clinical healing time of fracture in the observation group was significantly shorter than that in the control group(t=4.007, P=0.000). There was no significant difference in AOFAS score between the two groups one year after operation(t=0.417, P=0.678). In the observation group, there were 2 cases of pinhole infection and 3 cases of loss of reduction less than 2 mm. There were 3 cases of surgical incision infection in the control group. There was no significant difference in the incidence of complications between the two groups(χ2=0.446, P=0.504). CONCLUSION: Manual reduction combined with external fixation is safe and effective in the treatment of trimalleolar fracture under the guidance of CO theory, and the function of ankle joint recovers well after operation. This therapy has good clinical value.


Assuntos
Fraturas do Tornozelo , Fixadores Externos , Fixação de Fratura , Manipulação Ortopédica , Humanos , Fraturas do Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , População do Leste Asiático , Extremidade Inferior , Estudos Retrospectivos , Manipulação Ortopédica/instrumentação , Manipulação Ortopédica/métodos , Fixação de Fratura/instrumentação , Fixação de Fratura/métodos , Redução Aberta/instrumentação , Redução Aberta/métodos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos
6.
Orthop Surg ; 15(4): 1153-1164, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36855914

RESUMO

OBJECTIVES: At present, a variety of posterior lumbar internal fixation implantation methods have been developed, which makes it difficult for spine surgeons to choose. The stress distribution of the internal fixation system is one of the important indexes to evaluate these technologies. Common insertion technologies include Roy Camille, Magerl, Krag, AO, and Weinstein insertion techniques. This study aimed to compare the distribution of von Mises stresses in different screw fixation systems established by these insertion technologies. METHODS: Here, the three-dimensional finite element (FE) method was selected to evaluate the postoperative stress distribution of internal fixation. Following different pedicle screw insertion techniques, five single-segment transforaminal lumbar interbody fusion (TLIF) models were established after modeling and validation of the L1-S1 vertebrae FE model. RESULTS: By analyzing the data, we found that stress concentration phenomenon was in all the models. Additionally, Roy-Camille, Krag, AO, and Weinstein insertion techniques led to the great stress on lumbar vertebra, intervertebral disc, and screw-rod fixation systems. Therefore, we hope that the results can provide ideas for clinical work and development of pedicle screws in the future. It is worth noting that flexion, unaffected side lateral bending, and affected side axial rotation should be limited for the patients with cages implanted. CONCLUSIONS: Overall, our method obtained the results that Magerl insertion technique was the relatively safe approach for pedicle screw implantation due to its relatively dispersive stress in TLIF models.


Assuntos
Fixação Interna de Fraturas , Vértebras Lombares , Parafusos Pediculares , Fusão Vertebral , Estresse Mecânico , Fusão Vertebral/métodos , Vértebras Lombares/cirurgia , Análise de Elementos Finitos , Fixadores Internos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos
7.
Eur J Orthop Surg Traumatol ; 33(1): 191-197, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35001211

RESUMO

BACKGROUND: Distal femur fracture is considered one of the most common fractures due to high-energy traumas such as car accidents or low-energy traumas such as osteoporosis. Locking plates are orthopedic implants used for stabilized femur fracture. Thus, designing a bone plate fitted exactly with the patient's bone and correctly fixing bone segments are required for better fracture healing. OBJECTIVES: This study aims to design a bone plate based on anthropometric characteristics of patients' femurs and compare performing custom-designed bone plates (CDBP) with the locking compression plate (LCP) by finite element method. MATERIALS AND METHODS: In this analytical study, a 3D model of four patients' femur and CDBP were firstly designed in MIMICS 19.0 based on the patient's femur anatomy. After designing the bone plate, the CDBPs and LCP were fixed on the bone and analyzed by finite element method (FEM) in ANSYS, and stress and strain of bone plates were also compared. RESULTS: The maximum principal stress for all 3D models of patients' fracture femur by CDBPs was stabilized better than LCP with a decrease by 39.79, 12.54, 9.49, and 20.29% in 4 models, respectively. Also, in all models, the strain of CDBPs is less than LCP. Among the different thicknesses considered, the bone plate with 5 mm thickness showed better stress and strain distribution than other thicknesses. CONCLUSION: Customized bone plate designed based on patient's femur anatomical morphology shows better bone-matching plate, resulting in increasing the quality of the fracture healing and fails to any need for additional shaping. TRIAL REGISTRATION NUMBER: Design and analysis of an implant were investigated in this study. There was no intervention in the diagnosis and treatment of patients and the study was not a clinical trial.


Assuntos
Placas Ósseas , Fraturas Femorais Distais , Fixação Interna de Fraturas , Humanos , Fenômenos Biomecânicos , Fraturas Femorais Distais/cirurgia , Fêmur/anatomia & histologia , Fixação Interna de Fraturas/instrumentação , Desenho de Equipamento , Análise de Elementos Finitos , Modelos Anatômicos
8.
Rev. méd. Maule ; 37(2): 28-36, dic. 2022. tab, ilus
Artigo em Espanhol | LILACS | ID: biblio-1428070

RESUMO

Tibial pilon fractures are a complex injury to treat due to the great involvement of soft and bone tissues. The classic surgical treatment is based on open reduction with internal fixation (ORIF), adding morbidity to the soft tissues, increasing the risk of complications. This has motivated the development of minimally invasive and/or percutaneous techniques to reduce complications, and with the advent of arthroscopy, achieve anatomical reductions. METHODS: A retrospective observational study of twelve patients with tibial pilon fractures who were treated in our center with minimally invasive and/ or percutaneous osteosynthesis with arthroscopic support was carried out between January 2019 and June 2021. Fractures were characterized using the AO/OTA classification for tibial pilon. Age, sex, fracture mechanism, exposure and initial management in the emergency department (cast immobilization or external fixation), definitive treatment, complications and clinical and functional evaluation twelve months after definitive osteosynthesis. For this last point, plantar flexion, dorsiflexion and the AOFAS and FAOS Score were measured. RESULTS: The operated patients were 12, 8 were men (67%) and 4 were women (33%). The average age was 49 (17-68) years. The definitive treatment was carried out after an average of 8 days (5-12 days). Surgical treatment schemes were as follows: percutaneous osteosynthesis with medial anatomical plate and arthroscopic support (OPAA), minimally invasive osteosynthesis with cannulated screws and arthroscopic support (OMIAA) and osteosynthesis with external circular guide and arthroscopic support (OTCAA). In the AOFAS Score, three patients had excellent results (≥ 90 points), 6 patients had good results (≥ 80 points) and 3 patients had acceptable results (≥ 70 points). In the FAOS Score, eight patients had over 80% (good results) and 4 patients had over 60% (accep - table results). DISCUSSION: Historically, tibial pilon fractures have been considered non-reconstructable and with poor long-term results. Initially this paradigm changed with the principles of Rüedi for the reconstruction of the tibial pilon and improve the results. ORIF has been widely used until today, it allows achieving an anatomical joint reduction, it allows to give stability and length to the fibula, graft contribution and sta - bilization with the medial plate. Today this concept is changing again, since the emphasis is on the care of the soft tissues to allow a better recovery of the patient and reduce the complications of the classic approach, it is in this context that the appearance of minimally invasive and/or percutaneous techniques with arthroscopic assistance has allowed us to have excellent functional and clinical results with less da - mage to the soft tissues. CONCLUSION: The proper management and care of the soft tissues in a high-energy fracture of the tibial pilon is essential to obtain favorable clinical results and thus achieve restoration of ankle function. Percutaneous and minimally invasive management has optimized management of the tibial pilon, redu - cing the rates of complications, amputation, and pri - mary arthrodesis.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Fraturas da Tíbia/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Fixação Interna de Fraturas/métodos , Artroscopia/métodos , Fraturas da Tíbia/patologia , Estudos Retrospectivos , Resultado do Tratamento , Fixação Interna de Fraturas/instrumentação
9.
Neurol India ; 70(Supplement): S123-S128, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36412358

RESUMO

Background: Occipito-cervical fixation (OCF) provides immediate rigid fixation to cranio-vertebral junction (CVJ); however, in current practice, the optimal occipito-cervical fixation method is arguable. Aim: The aim of this study was to test the safety and efficacy of a newly designed inside-outside occipital (OC) plate system for the treatment of cranio-vertebral junction instability. Material and Methods: Thirty-two patients of CVJ instability were treated using this new OC plate system. Safety and efficacy of this new OC plate was evaluated radiologically and clinically. Results: Follow-up period ranged from 9 to 23 months. During the follow-up, no implant failure, recurrent subluxation, or newly developed instability at adjacent levels occurred, except in one patient in whom C2 screw pullout occurred due to trauma. All patients showed a satisfactory fusion at three months follow-up examination. Conclusions: These preliminary results suggest that this OC plate system is a simple, safe, and effective method for providing immediate internal rigid fixation of the CV junction. Long-term results are needed to determine the superiority of this OC plate over other methods of occipital fixation.


Assuntos
Artrodese , Placas Ósseas , Vértebras Cervicais , Luxações Articulares , Instabilidade Articular , Osso Occipital , Humanos , Artrodese/efeitos adversos , Artrodese/instrumentação , Artrodese/métodos , Parafusos Ósseos/efeitos adversos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Osso Occipital/diagnóstico por imagem , Osso Occipital/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia
10.
Vet Comp Orthop Traumatol ; 35(6): 403-412, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36075271

RESUMO

OBJECTIVE: The aim of this study was to report the short-term clinical and radiographic outcome for the treatment of femoral capital physeal fractures with cortical positional screws in cats. STUDY DESIGN: Medical records and radiographs of cats with femoral capital physeal fractures stabilized with cortical positional screws were retrospectively reviewed. Signalment, bodyweight, femoral head affected, fracture classification, fracture reduction, implants, concurrent orthopaedic injuries, osteoarthritis, femoral neck osteolysis, complications and 6-week follow-up clinical results were recorded. A short- to long-term follow-up was performed by telephone questionnaire with the owners. RESULTS: Forty-six fractures in 39 cats met the inclusion criteria. In 45/46 fractures, radiographic signs of bone healing were present and 35/39 cats were assessed as walking normally by a veterinarian at 6-week follow-up. There was a significant increase in radiographic signs of osteoarthritis (p=0.037) and femoral neck osteolysis (p=0.001) on 6-week follow-up radiographs. Pre- and postoperative osteoarthritis and femoral neck osteolysis were not associated with clinical outcome. The mean follow-up period for the telephone questionnaire was 48 months (range, 5-147 months). Seven out of 25 owners reported a gait abnormality in the short- to long-term. CONCLUSION: Femoral capital physeal fractures in cats can be treated successfully with the use of cortical positional screws. This technique may be considered as an alternative to other primary fixation techniques and salvage procedures for the treatment of femoral capital physeal injuries in cats. This technique seemed successful in cats with a low-grade preoperative femoral neck osteolysis.


Assuntos
Parafusos Ósseos , Doenças do Gato , Fraturas do Fêmur , Osteoartrite , Osteólise , Animais , Gatos/cirurgia , Doenças do Gato/diagnóstico por imagem , Doenças do Gato/cirurgia , Epífises/diagnóstico por imagem , Epífises/lesões , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/veterinária , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/veterinária , Osteoartrite/etiologia , Osteoartrite/veterinária , Osteólise/etiologia , Osteólise/veterinária , Estudos Retrospectivos , Resultado do Tratamento , Parafusos Ósseos/veterinária
11.
J Orthop Surg Res ; 17(1): 78, 2022 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-35123519

RESUMO

PURPOSE: This study aims to introduce the "tripod" technique using cannulated compression screw and two anti-rotational K-wires for treatment of unstable scaphoid waist fracture nonunion, and to compare it with the single cannulated screw fixation technique in term of scaphoid union and surgical outcomes. METHODS: It was a retrospective study. From January 2014 to March 2020, 103 consecutive patients with scaphoid waist fracture nonunion treated with the tripod fixation and bone grafting (n = 45) or with single cannulated compression screw and bone grafting (n = 58) were included. All the procedures were performed by the same hand surgery team, and autologous cortico-cancellous radius bone graft was used for bony reconstruction. The minimal follow-up period was 12 months. The union rate and the time to union, range of motion (ROM), grip strength, Visual Analogue Scale (VAS), Quick Disabilities of the Arm, Shoulder and Hand (DASH) score and modified Mayo Scores at the last visit were compared. RESULTS: In tripod fixation group, bony union was achieved in all patients at the mean of 14.8 ± 3.8 weeks, while in the single cannulated screw fixation group the bony union rate was 94.8% (55/58) and the time to union was 17.6 ± 3.6 weeks. The difference of time to union was statistically significant (p = 0.027), but not for bony union rate (p = 0.122). At the last visit, no significant difference was found with respect to any clinical and radiographic outcome measures (all p > 0.05). The overall rate of complications was not significantly different between two groups (15.6% vs 10.3%, p = 0.430). CONCLUSIONS: Tripod fixation technique with headless compression screw and two K-wires is a safe and effective technique for treatment of scaphoid nonunion fixation and can be considered to use in practice, especially for those potentially rotationally unstable cases.


Assuntos
Parafusos Ósseos , Transplante Ósseo/métodos , Fixação Interna de Fraturas , Fraturas não Consolidadas/cirurgia , Osso Escafoide/lesões , Adulto , Feminino , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas não Consolidadas/diagnóstico por imagem , Humanos , Masculino , Amplitude de Movimento Articular , Estudos Retrospectivos , Osso Escafoide/cirurgia , Resultado do Tratamento
12.
J Orthop Surg Res ; 17(1): 66, 2022 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-35109905

RESUMO

BACKGROUND: Angular stable plates were introduced two decades ago as a promising treatment for fixation of displaced fractures of the proximal humerus (PHF). However, high rates of adverse events and reoperations have been reported. One frequent reason is secondary penetration of screws into the glenohumeral joint, due to sinking of the fracture or avascular head necrosis. To prevent joint penetrations angular stable plates with smooth locking pegs instead of locking screws have been developed. The aim of the present study was to investigate whether blunt pegs instead of pointed screws reduced the risk of secondary penetration into the glenohumeral joint during fracture healing after operatively treated PHFs. METHODS: From two different patient cohorts with displaced PHFs (60 treated with PHILOS plate with screws and 50 with ALPS-PHP plate with pegs), two groups were matched according to fracture type AO/OTA 11-B2 and 11-C2 and age (55-85 years). They were followed up at 3, 6 and 12 months. Primary outcome was radiographic signs of peg or screw penetrations into the glenohumeral joint at 12 months. Secondary outcomes were Oxford shoulder score (OSS) and Constant Score (CS) and radiographic signs of avascular humeral head necrosis (AVN). RESULTS: Eighteen PHILOS patients with B2 and C2 fractures could be matched with a corresponding group of 18 operated with ALPS-PHP with pegs. The number of penetrations of pegs and screws were equal between the two groups and the development of avascular head necrosis did not differ either. The functional outcomes for both OSS and CS at 12 months was clearly in favor of patients without joint penetrations in both groups. CONCLUSION: We found no differences in the number of screw or peg penetrations in the PHILOS and ALPS-PHP group and the occurrence of AVN was equal. Joint penetrations led to inferior functional outcomes at 1 year. The ClinicalTrials.gov identifier 20/11/12 prospectively for the Philos Group is NCT01737060, and for the ALPS group 11/03/20 retrospectively is NCT04622852.


Assuntos
Placas Ósseas/efeitos adversos , Parafusos Ósseos/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Fraturas do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Humanos , Pessoa de Meia-Idade , Necrose , Complicações Pós-Operatórias , Estudos Retrospectivos , Ombro , Fraturas do Ombro/diagnóstico por imagem , Resultado do Tratamento
13.
Comput Math Methods Med ; 2022: 2008668, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35154357

RESUMO

Memory alloy patella claws for treating patella fractures have been used for more than 30 years with many desirable features including fast healing, quick recovery, and avoidance of top abrasion of Kirschner wires and other complications. However, there are many models and it is difficult to choose the accurate claw for the patient. In this study, a finite element model of the butterfly-shaped patellar claw made of shape memory alloy was established, its mechanical structure was analyzed, and its clinical application was monitored. We used Solidworks Simulation software for modeling and mainly analyzed the force of the compression ring of the butterfly-shaped patellar claw. Clinically, we chose a closed fresh patella fracture case. After finite element analysis, the maximum stress that the compression ring of the butterfly-shaped patellar claw can withstand is 568.1 MPa. In this range, it always has elastic deformation resistance. The butterfly-shaped patella claw is fixed on the patella and will not break when subjected to a maximum force of 150 N on the encircling arm, and at the same time, there will be no pressure failure due to plastic deformation. A total of 27 cases were clinically used for the assessment of the clinical efficacy of the newly designed butterfly-shaped patella claws. The average follow-up time was 15.5 months, and the average fracture healing time was 8-12 weeks. All patients can get out of bed with crutches within 2 to 3 days after surgery. Among them, there were 15 cases with excellent functional ratings, 10 cases with good ratings, 2 cases with acceptable ratings, and no cases with poor ratings. The designed butterfly-shaped patella claws can provide an effective method for the treatment of patella fractures.


Assuntos
Fixação Interna de Fraturas/instrumentação , Fixadores Internos , Fraturas Intra-Articulares/cirurgia , Patela/lesões , Patela/cirurgia , Adolescente , Adulto , Fenômenos Biomecânicos , Biologia Computacional , Simulação por Computador , Desenho Assistido por Computador/estatística & dados numéricos , Módulo de Elasticidade , Feminino , Análise de Elementos Finitos , Fixação Interna de Fraturas/estatística & dados numéricos , Humanos , Fixadores Internos/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Níquel , Desenho de Prótese , Ligas de Memória da Forma , Software , Estresse Mecânico , Resistência à Tração , Titânio , Resultado do Tratamento , Adulto Jovem
14.
Sci Rep ; 12(1): 325, 2022 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-35013408

RESUMO

Closed reduction and internal fixation with three cannulated compression screws is a common method for treating femoral neck fractures in young and middle-aged patients. Protocols including the inverted triangle configuration and dispersion of the screws still needed further supports. The purpose of this study was to explore a novel oblique triangle configuration (OTC) of three screws in fixing femoral neck fractures based on the morphology of the femoral neck isthmus (FNI). The computer-aided design modules were used to explore the ideal spatial configuration with largest triangle by three parallel screws. A univariate evaluation model was established based on the oval-like cross-section of the FNI. When the three screws were positioned by the OTC, Inverted Equilateral Triangle Configuration (IETC), and the Maximum Area Inverted Isosceles Triangle Configuration (MA-IITC) respectively, the proportion of area and circumference in the cross-section of FNI and the changing trend of proportion were compared under various torsion angles, eccentricity, and cross-sectional area of FNI. The area and circumference ratios of the parallel screws using the OTC method were significantly higher than in the IETC and MA-IITC groups. In the univariate evaluation model, the OTC area ratio and circumference ratio remained stable under the different femoral neck torsion angles, FNI cross-sectional area, and eccentricity. The OTC method provided an ideal spatial configuration for the FNA fixation with the largest area using three parallel screws. The position of the posterior screw was also away from the metaphyseal artery, potentially reducing the possibility of vascular injury and screw penetrating.


Assuntos
Parafusos Ósseos , Desenho Assistido por Computador , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/instrumentação , Desenho de Prótese , Fenômenos Biomecânicos , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/fisiopatologia , Fixação Interna de Fraturas/efeitos adversos , Humanos , Estresse Mecânico
15.
Sci Rep ; 12(1): 368, 2022 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-35013494

RESUMO

To elucidate the accuracy, efficacy, and safety of percutaneous iliosacral screw (ISS) and trans-iliac trans-sacral screw (TITS) insertion using a single C-arm fluoroscopy intensifier. Additionally, the potential risk factors that might cause mal-positioned screws were identified. Patients with pelvic ring injuries who underwent percutaneous screw fixation in a single medical institute were divided into an ISS group (n = 59) and a TITS group (n = 62) and assessed. The angles deviated from ideal orientation (ADIO) of the implanted screw were measured, and potential risk factors for mal-positioned screws were analyzed. Overall, the reduction quality of the pelvic ring was good or excellent in 70 patients (82.4%) by Matta's criteria and in 48 patients (56.5%) by Lefaivre's criteria. ADIO measurements of the ISS and TITS groups via multi-planar computed tomography were 9.16° ± 6.97° and 3.09° ± 2.8° in the axial view, respectively, and 5.92° ± 3.65° and 2.10° ± 2.01° in the coronal view, respectively. Univariate statistical analysis revealed body mass index as the single potential risk factor of mal-positioned screws. With careful preoperative planning and intraoperative preparations, placing ISS and TITS under the guidance of single C-arm fluoroscopy intensifier is a reliable and safe technique. Caution should be exercised when performing this procedure in patients with a high body mass index.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Ossos Pélvicos/cirurgia , Radiografia Intervencionista/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Feminino , Fluoroscopia , Fixação Interna de Fraturas/efeitos adversos , Fraturas Ósseas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/efeitos dos fármacos , Ossos Pélvicos/lesões , Complicações Pós-Operatórias/diagnóstico por imagem , Valor Preditivo dos Testes , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
16.
Sci Rep ; 12(1): 279, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34997069

RESUMO

The study goal was to evaluate the distances from the radial (RN), the musculocutaneous (MN) and axillary nerves (AN) and the medial neurovascular bundle of the upper arm to a minimally invasive applied plate and to define its relation to the RN during different degrees of malrotation during MIPO. The sample involved ten upper extremities. Application of a PHILOS plate was performed through a Delta-split. Intervals between the AN, MN, RN and the medial vascular bundle were defined at various positions. The humeral shaft was artificially fractured at a height of about the mean of the plate. The distal fragment was brought into 15° and 30° internal (IR) as well as external rotation (ER) and here, the plate's relation to the RN was evaluated. The medial neurovascular bundle intersected the plate at its distal part in two specimens. Regarding the distances from the RN to the plate during different rotation positions the distances became significantly longer during ER, respectively shorter during IR. The medial neurovascular bundle and the RN were identified as the main structures at risk. Care must be taken during distal screw placement and malrotation exceeding 15° must be avoided during MIPO.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Fixação Interna de Fraturas/efeitos adversos , Consolidação da Fratura , Humanos , Fraturas do Úmero/patologia , Úmero/lesões , Úmero/patologia , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Traumatismos dos Nervos Periféricos/etiologia , Nervo Radial/lesões
18.
J Trauma Acute Care Surg ; 92(3): 574-580, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34686638

RESUMO

BACKGROUND: The high morbidity following surgical interventions on the chest wall because of large incisions often prevents surgeons from operative rib fracture treatment. Minimally invasive approaches to the intrathoracic side of the rib could allow for smaller incisions with lower morbidity while maintaining stability of fixation. The aim of this study was to explore the biomechanical competence of intrathoracic versus extrathoracic plating in a human cadaveric rib fracture model and investigate the effect of plating using two versus three screws per fracture fragment. METHODS: Twenty pairs of fresh-frozen human cadaveric ribs from elderly female donors aged 82.4 ± 7.8 years were used. First, the stiffness of each native rib was calculated via nondestructive (2 N-5 N) biomechanical testing under two loading conditions: ramped two-point bending and combined ramped tensile bending with torsional loading. Second, the ribs were fractured under three-point bending with their intrathoracic side put under tensile stress. Third, specimens were assigned to four groups (n = 10) for either intrathoracic or extrathoracic plating with two or three screws per fragment. Following instrumentation, all ribs were dynamically tested over 400,000 cycles under combined sinusoidal tensile bending with torsional loading (2 N-5 N at 3 Hz). Finally, all specimens were destructively tested under ramped two-point bending. RESULTS: Following instrumentation and cyclic testing, significantly higher construct stiffness was observed for intrathoracic vs. extrathoracic plating under anatomical loading conditions (p ≤ 0.03). No significant differences were detected for implant subsidence after plating with two or three screws per fragment (p ≥ 0.20). CONCLUSION: This study demonstrates significantly higher construct stiffness following intrathoracic over extrathoracic plating, thus indicating superior plate support of the former. In the clinical context, using only two instead of three screws per fragment not only could maintain stability of fixation but also decrease surgery time and costs, and allow for smaller incisions with lower morbidity. LEVEL OF EVIDENCE: Therapeutic/Care Management; Level V.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fraturas das Costelas/cirurgia , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Feminino , Humanos
19.
Biomed Res Int ; 2021: 5911868, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34859101

RESUMO

OBJECTIVE: To analyze the effect of PFNA-II internal fixation on hip joint recovery and quality of life (QOL) in patients with lateral-wall dangerous type of intertrochanteric fracture. METHODS: One hundred and twelve patients with lateral-wall dangerous type of intertrochanteric fracture who underwent surgical treatment in our hospital from May 2017 to May 2019 were selected as the participants of the study. Based on the treatment method, all the enrolled patients were divided into two groups: proximal femoral nail antirotation (PFNA group; n = 59) who received closed reduction and minimally invasive PFNA internal fixation and dynamic hip screw group (DHS; n = 53) who received internal fixation. The clinical indicators, curative effect, hip function score, pain degree, postoperative QOL score, and complications were compared between the two groups. RESULTS: The operation time, intraoperative blood loss, postoperative drainage volume, and the incidence of postoperative complications in PFNA group were statistically lower than those in DHS group (P < 0.05). The curative effect in PFNA group was notably better than that in DHS group. There were no significant differences in scores of hip function, visual analogue scale (VAS), and QOL between the two groups before operation (P > 0.05). However, the hip function score and QOL score increased in both groups after surgery, and the increase was more significant in the PFNA group, while the VAS score decreased in both groups, and the decrease in PFNA group was more significant (P < 0.05). CONCLUSION: PFNA internal fixation for the treatment of lateral-wall dangerous type of intertrochanteric fracture has the advantages of short operation time, less intraoperative blood loss, effective improvement of hip joint function, and fewer postoperative complications, which is worthy of clinical application.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Perda Sanguínea Cirúrgica , Pinos Ortopédicos , Parafusos Ósseos , Feminino , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura , Fraturas do Quadril/fisiopatologia , Fraturas do Quadril/reabilitação , Articulação do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento , Escala Visual Analógica
20.
Comput Math Methods Med ; 2021: 2562575, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34887939

RESUMO

The aim of this work was to explore the effects of Gamma nail internal fixation for intertrochanteric fracture of femur by X-ray film classification and recognition method based on artificial intelligence algorithm. The study subjects were 100 elderly patients with intertrochanteric fracture of femur admitted to hospital. The cases were diagnosed as elderly (over 60 years old) femoral intertrochanteric fractures by X-ray or CT. They were divided into two groups, with 50 persons in each group: one group used the X-ray film evaluation image guidance based on the artificial intelligence algorithm (research group), and the other group did not use algorithmic guidance (control group). The results showed that the segmentation effect of the proposed algorithm was similar to the gold standard segmentation result, indicating that the algorithm was effective and feasible in the segmentation of fractures and bones. The global level set algorithm was set as the control. The ultimate measurement accuracy (UMA) value of the algorithm group was (1.77 ± 0.22), and the UMA value of the global level set algorithm group was (3.42 ± 0.36), indicating that the image processed by the algorithm group had obvious numerical effect, high accuracy, and good retention of details. The operation time, intraoperative blood loss, incision length, hospital stay, weight-bearing time, and fracture healing time of the two groups were all better than those of the control group. One month after surgery, the Harris score of the algorithm group was 67, and that of the control group was 51, with a 16-point difference between the two groups (p < 0.05). The patient had less pain and fast recovery speed, indicating that it was a good way to treat elderly intertrochanteric fractures with the nursing effect of X-ray Gamma nail internal fixation based on an artificial intelligence algorithm. The artificial intelligence algorithm not only can be applied to the Gamma nail internal fixation of elderly patients with intertrochanteric fractures but also can be applied to the X-ray image processing of other fractures and other surgical methods to provide effective treatment for fracture patients.


Assuntos
Inteligência Artificial , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Pinos Ortopédicos , Biologia Computacional , Feminino , Fraturas do Fêmur/enfermagem , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/enfermagem , Fraturas do Quadril/enfermagem , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Prognóstico , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...